KDGC88S 50 Hz

Ratings
Standby Power KVA 110 KW 88 Prime Power KVA 100 KW 80 Voltage type 50Hz,380/220V, 3 phases and 4 wires
Performance Data
Engine Brand & Model Cummins 6BT5.9-G2 Alternator Brand & Model Leroy Somer LSA44.3 S5 Control System Deepsea DSE6120 Standard Noise Level@7m (Soundproof Sets) 75 dBA Circuit Breaker Type 3 Poles MCCB Frequency & Phase 50hz 3Phases + 4Wires Engine Speed (RPM) 1500 Fuel Consumption (L/hr) 100% Load 24.2 75% Load 18.2 50% Load 13.3 25% Load 6.66
Dimensions and Weights
Content Open type Soundproof Sets Dimensions: (mm) L 2250 2900 W 860 1100 H 1440 1650 Weights (kg) 1210 1900
20 ft' and 40 ft' Container soundproof canopy:
1. The canopy is remodeled from 20 and 40 feet container;
2. The soundproof level is 75 dB(A) within 1 meter from engine;
3. According to IP23 standard, the canopy uses anti-corrosion polyester paint and can sustain high temperature and high pressure, which is fire-proof, water-proof, rust-proof and static-proof. Moreover, high-quality paint is sprayed through over 10 procedures via advanced painting technology such as degreasing, rinsing, de-rusting, parching and curing;
4. Three large doors on each side and one end of the container are designed for convenient installation;
5. The canopy is spacious inside to allow enough area for maintenance;
6. The canopy is equipped with good air inlet and outlet system, ensuring steady running of gen-sets.
7. The silencer installed can efficiently reduce noise during operation, making it possible for generators to run at any moment. Besides, four-hour test makes the noise level meet requirements.
8. Lifting eyes and forklift holes are designed for easy transportation. The canopy can be used in the open air for easy and convenient operation.
Hot Tags: 110kva Standby Diesel Generator, China, suppliers, manufacturers, factory
110kVA Standby Diesel Generator – Reliable Industrial Backup Power Solution
When I talk with customers who need stable backup power for medium-sized operations, the 110kVA Standby Diesel Generator often becomes one of the most balanced choices. It’s powerful enough for industrial loads, but still efficient for long standby operation without unnecessary fuel waste.
At camda New Energy Equipment Co., Ltd., we have been building generator sets since 1998. With a production capacity of 3000 units per year, I’ve seen this power range widely used in factories, commercial buildings, hospitals, telecom stations, and construction sites where downtime is simply not acceptable.

This 110kVA standby diesel generator is designed to take over immediately when grid power fails. With a Cummins-powered engine system, it delivers stable output, fast response, and long service life under real working conditions.
If you are searching for a 110kVA diesel generator for industrial backup power, a Cummins standby generator set for commercial use, or a reliable emergency power system for critical facilities, this model is built for practical performance—not just lab numbers.
From my experience, 110kVA is a very “safe” capacity for many medium-scale users. It avoids the cost of oversized systems while still providing enough reserve power for essential operations.
Common applications include:
Small to medium factories
Commercial complexes and office buildings
Telecommunication base stations
Hospitals and clinics
Construction projects
Agricultural facilities
This balance between cost, fuel consumption, and output is why it remains a strong-selling model in global markets.
The operation is simple, but the system is designed for fast and reliable response.
Under normal conditions, utility power supplies electricity and the generator remains in standby mode.
When a power outage occurs, the Automatic Transfer Switch (ATS) detects the failure and sends a start signal.
The diesel engine starts within seconds, reaches rated speed, and drives the alternator to produce stable electricity.
The load is automatically transferred from the grid to the generator, ensuring continuous power without manual intervention.
Once grid power returns, the system switches back and shuts down safely.
The Cummins engine is widely known for durability, stable output, and long operational life under heavy-duty conditions.
Ensures consistent voltage and frequency suitable for sensitive industrial and commercial equipment.
Advanced fuel injection system helps reduce fuel consumption while maintaining strong output performance.
Real-time monitoring of voltage, current, frequency, temperature, oil pressure, and operating status.
Reinforced base frame reduces vibration and improves long-term stability.
| Feature | 110kVA Diesel Generator | Gasoline Generator | Battery Backup System |
|---|---|---|---|
| Power Output | Medium-High | Medium | Low |
| Operating Duration | Long | Moderate | Short |
| Industrial Suitability | Excellent | Limited | Not suitable |
| Fuel Efficiency | High | Medium | High but limited runtime |
| Maintenance Cost | Low | Medium | Low |
Source: Industrial Backup Power System comparison data and engineering field reports.
| Item | Specification |
|---|---|
| Generator Type | Standby Diesel Generator |
| Power Rating | 110kVA |
| Engine Brand | Cummins |
| Phase | Three Phase |
| Frequency | 50Hz / 60Hz |
| Cooling System | Water Cooled |
| Start System | Electric Start with ATS |
| Control Panel | Digital Smart Controller |
| Voltage | Customizable |
| Certification | CE Certified |
Source: Camda engineering specification sheet.
Supports production continuity during unexpected outages.
Ensures critical medical systems remain operational.
Maintains stable communication networks.
Supports elevators, lighting, and security systems.
Provides reliable temporary power supply.
Supports irrigation and storage systems.

Every generator goes through a strict production and inspection process:
Material inspection
Engine performance testing
Alternator inspection
Frame assembly and welding
Electrical system installation
System integration
Full load testing
Final quality inspection
No unit is shipped without passing full load verification.
| Test Item | Purpose |
|---|---|
| Load Test | Ensure stable power output |
| Voltage Test | Check accuracy of output |
| Frequency Test | Verify electrical stability |
| Protection Test | Confirm safety response |
| Controller Test | Validate monitoring system |
Source: Camda factory quality control process records.
Over the years, customers choose us not only for equipment, but for reliability and long-term support.
25+ years manufacturing experience
3000 units annual production capacity
Strong engineering and service team
Global project delivery experience
Strict quality control system
Fast production lead time (15–35 days)
Customized generator solutions
To ensure safe transport, we use:
Export-grade wooden cases
Steel frame reinforcement
Protective wrapping materials
Shipping options include sea freight, land transport, railway, and air freight for urgent deliveries.
Yes, it is widely used in factories, commercial buildings, and infrastructure projects.
Yes, with ATS integration it starts automatically during power failure.
It is powered by a Cummins diesel engine.
Typically 15–35 days depending on configuration and order quantity.
The 110kVA Standby Diesel Generator is a practical and reliable solution for businesses that need stable backup power. It combines efficiency, durability, and fast response to ensure uninterrupted operations.
With Camda’s manufacturing experience and strict quality system, this generator is built to perform when power stability matters most.
This website uses cookies to ensure you get the best experience on our website.