Home > Products > Diesel Generator Set > Cummins Powered Diesel Generator > 27 KVA Standby Diesel Generator with CE and ISO verified

27 KVA Standby Diesel Generator with CE and ISO verified

    27 KVA Standby Diesel Generator with CE and ISO verified

    Diesel generator set from 18 to 1320 kW; Cummins engine; Leroy somer or Stamford alternator; Factory price and factory outlet; CE/ISO and BV/TUV/SGS verified; OEM and ODM manufacturer; ...
  • Share:
  • Contact us Inquiry
  • E-mail:sf@camda.cc
    WhatsApp:8613712859644

KDGC21S




Ratings

Standby PowerKVA27
KW21
Prime  PowerKVA23
KW18
Voltage type50Hz,380/220V, 3 phases and 4 wires

Performance Data

Engine Brand & ModelCummins  4B3.9-G2
Alternator Brand & ModelLeroy Somer  LSA40 M7
Control SystemDeepsea DSE6120
Standard Noise Level@7m (Soundproof Sets)75 dBA
Circuit Breaker Type3 Poles MCCB
Frequency & Phase50hz 3Phases + 4Wires
Engine Speed (RPM)1500
Fuel Consumption (L/hr)100% Load5.9
75% Load4.8
50% Load3.2
25% Load1.8

Dimensions and Weights

ContentOpen typeSoundproof Set
Dimensions: (mm)L17002370
W7101100
H12701650
Weights (kg)6971309

Tips:When temperature and pressure of cooling water are abnormal.

No.Malfaunction and causesRemedy
1There is air in the water pipe, which results no or little water from the outlet water pipe when the engine is working and causes high temperature of water.Loosen the joint of termometer on the outlet pipe, exhaust the air until the water canflow fluently, then tighten all the joints of the water pipelines.
2Low pressure of cooling water:
(1)Low water level
(2)Block of cylinder water heat exchanger or radiator
(3)The air enters the system from cylinder water pump suction point
(4)The pressure cap is damaged or incorrect
(5)The pressure meter isn’t accurate.
(6)The line of pressure meter is blocked or the valve is closed
(7)The leak of water pump seal
(8)The water-cooled exhaust manifold gasket is burned
(9)The water-cooled exhaust manifold gasket is broken
(1)Add coolant
(2)Clean or replace
(3)Repair the leakage, remove the air from the system
(4)Adjust or replace
(5)Compare with the main meter, change the meter
(6)Change the line, open the valve
(7)Repair the water pump
(8)Replace the gas
(9)Replace the manifold gasket.
3Low temperature of cylinder water:
(1) The pressure meter isn’t accurate
(2) Fault with thermostat
(1)Compare with the main meter, change the meter
(2)Replace the thermostat
4High temperature of cylinder water:
(1) The pressure meter isn’t accurate.
(2) Fault with thermostat
(3) There is leakage in the cooling system
(4) Bad coolant cycle
(5) Aging of cylinder water pump or the bad effect of sealing
(6) Solidification of coolant
(7) Combustion of flammable tube
(8) Late ignition time
(9) Cracked cylinder head
(10)The cylinder is broken
(1)Lower down the temperature of engine slowly,compare to the main meter and then adjust
(2)Replace
(3)Remove air from the cooling system
(4)Find the reason for overload then correct check the whole cooling system
(5)Replace or repair the water pump
(6)Unfreeze the whole cooling system before starting the machine
(7)Change the flammable head
(8)Retiming the ignition
(9)Change the cylinder head
(10)Change the cylinder

Hot Tags: 27 KVA Standby Diesel Generator with CE and ISO verified, China, suppliers, manufacturers, factory


<span style="color: rgb(0, 0, 0); font-size: 16px;">27 KVA <a href='https://camda-generator.com/tag/standby-diesel-generator' target='_blank' class='key-tag'><font><strong>Standby Diesel Generator</strong></font></a> with CE and ISO Verified | <a href='https://camda-generator.com/tag/camda' target='_blank' class='key-tag'><font><strong>camda</strong></font></a></span>

27 KVA Standby Diesel Generator with CE and ISO verified

When I work with customers on backup power planning, I always start from a simple reality: electricity failure never gives warning. It just happens. That’s why a small but stable system like the 27 KVA standby diesel generator with CE and ISO verified is often the most practical solution for many businesses.

At Camda New Energy Equipment Co. Ltd., we don’t treat generators as simple machines. I see them more like a safety layer for business operations—quiet when everything is fine, but absolutely critical when things go wrong.


1. What This 27 KVA Standby Generator Is Built For

This 27 KVA diesel generator is designed for standby use. It stays idle during normal grid power and automatically starts when electricity fails. The CE and ISO verification ensures that the system follows international safety and manufacturing standards.

I usually explain it in simple terms: it’s like a backup worker who never sleeps, always ready to step in when needed.

SpecificationValueSource
Rated Power27 KVA / approx. 22 kWISO 8528 Generator Standard
CertificationCE / ISO VerifiedSGS Certification Report
Start Time5–10 seconds (ATS system)Schneider ATS Technical Guide

2. Working Principle in Simple Language

Inside the generator system, there are three main parts: diesel engine, alternator, and controller. I always explain it in a way that even non-technical users can understand.

  • Engine = produces mechanical energy

  • Alternator = converts energy into electricity

  • Controller = manages start, stop, and protection


When power outage happens, the automatic transfer switch (ATS) detects it immediately and starts the generator within seconds. The load is transferred smoothly without manual operation.

ComponentFunctionReference
Cummins Diesel EngineMechanical power generationCummins Technical Manual
Brushless AlternatorStable electricity outputIEC 60034 Standard
Smart ControllerMonitoring & protection systemDeep Sea Electronics Guide

3. Key Features of the 27 KVA Standby Diesel Generator

From real-world installations, I notice customers care most about reliability, fuel efficiency, fast response, and low maintenance. This generator is designed exactly around those needs.

  • Automatic start with ATS system

  • Stable voltage output under load changes

  • Fuel-efficient Cummins-powered engine system

  • Compact structure for easy installation

  • Optional silent enclosure for low noise operation

FeatureBenefitIndustry Standard
Automatic StartFast recovery during outagesIEC 60947 ATS Standard
Fuel EfficiencyReduced operational costCummins Performance Report
Noise Reduction OptionSuitable for urban areasISO 3744 Acoustic Standard

4. Technical Strength Behind the System

At Camda, every generator is built as a complete system, not just assembled parts. We use globally recognized components to ensure stable long-term operation.

The Cummins Powered Diesel Generator platform is widely known for durability, fuel efficiency, and stable power output under continuous load conditions.

Before shipment, every unit undergoes load testing from 0% to 100% to ensure performance under real working conditions.

Technical ElementAdvantageSource
Cummins Engine TechnologyLong service life & stabilityCummins Global Datasheet
Brushless AlternatorLow maintenance operationIEC 60034 Standard
Load Testing SystemVerified real-world performanceISO 8528 Testing Protocol

5. Application Industries

The 27 KVA standby diesel generator is widely used in small to medium power demand environments where reliability matters more than size.

  • Small factories and workshops

  • Telecom base stations

  • Hospitals and clinics

  • Commercial buildings

  • Construction sites and temporary power supply

In many cases, even a few seconds of power loss can cause system failure or financial loss, so standby power is not optional—it is necessary.




6. Manufacturing Process and Quality Control

From steel frame production to final testing, every step is controlled. I always believe quality is not something checked at the end—it is built into the process.

StageProcessStandard
Frame FabricationSteel cutting and weldingISO 9001 System
AssemblyEngine and alternator integrationFactory Inspection Process
Final TestingFull load performance testISO 8528 Standard

We also follow ISO14001 environmental management standards and OHSAS safety systems to ensure responsible and safe manufacturing practices.


7. Why Choose Camda Standby Power Solutions

From my experience, customers don’t just buy a generator—they buy confidence during unexpected power failure.

Camda has been manufacturing generator sets since 1998 and cooperates with global brands like Cummins, Perkins, Yuchai, Stamford, Leroy Somer, ABB, and Schneider. This gives us strong system integration capability and global reliability standards.

We also provide complete support including design, production, testing, packaging, shipping, and after-sales service.


8. Frequently Asked Questions (FAQ)

Q1: How fast does the generator start?
Typically within 5–10 seconds after power failure using ATS system.

Q2: Is it suitable for continuous operation?
It is mainly designed for standby use, but can run extended hours with proper maintenance.

Q3: Does it include CE and ISO certification?
Yes, the product is CE certified and ISO verified by SGS inspection standards.

Q4: Is noise control available?
Yes, optional silent enclosure reduces noise significantly for urban environments.

Q5: What is the delivery time?
Normally 15–35 days depending on specifications and order quantity.




Final Thoughts

A standby generator is not something people notice every day, but when power fails, it becomes the most important system in operation.

The 27 KVA Standby Diesel Generator with CE and ISO verified is designed for that exact moment—fast response, stable output, and long-term reliability that businesses can depend on.