KDGC35S 50HZ

camda is devoting to provide high quality Diesel Generator Sets for all of our customers. Please feel free to contact us if you need any support in diesel generator set.
Ratings
Standby Power KVA 44 KW 35 Prime Power KVA 40 KW 32 Voltage type 50Hz,380/220V, 3 phases and 4 wires
Performance Data
Cummins heavy-duty diesel engine - Rugged 4-cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes.
Engine Brand & Model Cummins 4BT3.9-G1/4BT3.9-G2 Alternator Brand & Model Leroy Somer LSA42.3 S5 Control System Deepsea DSE6120 Standard Noise Level@7m (Soundproof Sets) 75 dBA Circuit Breaker Type 3 Poles MCCB Frequency & Phase 50hz 3Phases + 4Wires Engine Speed (RPM) 1500 Fuel Consumption (L/hr) (100% Load) 8
Dimensions and Weights
Content Open type Soundproof Sets Dimensions: (mm) L 1700 2370 W 760 1100 H 1400 1650 Weights (kg) 850 1462
Deepsea control system - The electronic control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto-shutdown at fault detection.

Hot Tags: 45 KVA 35 kW Standby power Diesel Generator, China, suppliers, manufacturers, factory
45 KVA 35 kW Standby Power Diesel Generator
When I talk about standby power systems, I usually start from real situations instead of technical brochures. A power failure in a factory, hospital, or telecom station is not just an inconvenience—it directly affects production, safety, and revenue. This is exactly where the 45 KVA 35 kW Standby Power Diesel Generator becomes a critical part of the whole system.
I have worked with different diesel generator systems for years, and I can say clearly: a good standby generator is not about having the highest numbers, but about stability, fast response, and long-term reliability under real load conditions.

The 45 KVA 35 kW Standby Diesel Generator is designed for automatic backup power. It stays idle during normal grid operation, but starts immediately when the main power fails.
In simple words, it acts like an insurance policy for electricity. It doesn’t need attention every day, but when something goes wrong, it must work instantly without failure.
| Specification | Value | Reference Source |
|---|---|---|
| Rated Power | 45 KVA / 35 kW | ISO 8528 Standard |
| Frequency | 50/60 Hz | IEC Electrical Standard |
| Start Time | 5–10 seconds (ATS system) | Schneider ATS Technical Guide |
Inside this generator system, there are three key components: diesel engine, alternator, and control system.
I like to explain it like this: the engine produces mechanical energy, the alternator converts it into electricity, and the controller acts like the brain that decides when to start or stop.

When the power grid fails, the automatic transfer switch (ATS) detects the problem and sends a signal. The generator starts automatically and takes over the load within seconds.
| Component | Function | Technical Reference |
|---|---|---|
| Diesel Engine (Cummins Powered) | Mechanical power generation | Cummins Engine Manual |
| Alternator (Stamford / Leroy Somer) | Electricity conversion | IEC 60034 Standard |
| Control Panel (Smart Controller) | Monitoring & protection | Deep Sea Electronics Guide |
From real installation experience, I can say that users care most about four things: fast start, stable voltage, low fuel consumption, and easy maintenance.
Automatic start with ATS system
Stable voltage output under load changes
Low fuel consumption diesel engine design
Compact structure for easy installation
Optional silent canopy for noise control
| Feature | Benefit | Industry Benchmark |
|---|---|---|
| Automatic Start | Fast power recovery | IEC 60947 ATS Standard |
| Fuel Efficiency | Lower operating cost | Cummins Fuel Report |
| Soundproof Design | Reduced noise pollution | ISO 3744 Acoustic Standard |
At camda New Energy Equipment Co. Ltd., we build generator systems with one goal in mind: long-term stability in real operating environments.
We use globally recognized engine brands such as Cummins, Perkins, Yuchai, and combine them with Stamford or Leroy Somer alternators to ensure consistent performance.
Every generator is tested under different load levels before delivery. This step is critical because real-world conditions are always more complex than factory no-load tests.
| Advantage | Impact | Source |
|---|---|---|
| Cummins Engine Technology | Long service life, stable output | Cummins Global Datasheet |
| Brushless Alternator | Low maintenance requirement | IEC 60034 |
| Load Testing Before Shipment | Performance validation | ISO 8528 Testing Standard |
This 45 KVA 35 kW standby diesel generator is widely used in different industries where continuous power supply is critical.
Small and medium manufacturing factories
Hospitals and healthcare facilities
Telecommunication base stations
Commercial buildings and shopping centers
Construction sites and temporary power systems
It is especially useful in places where even a short power interruption can cause financial loss or safety risks.
From raw material selection to final testing, every generator follows a strict production process. I always believe that quality is not checked at the end—it is built into every step.
| Stage | Process | Standard Reference |
|---|---|---|
| Frame Fabrication | Steel cutting & welding | ISO 9001 System |
| Assembly | Engine + alternator integration | Factory Inspection Protocol |
| Final Testing | 0%-100% load test | ISO 8528 Compliance |
We also follow ISO14001 environmental standards and OHSAS safety management systems to ensure responsible manufacturing and safe production environments.

From my experience in the power generation industry, customers don’t just buy a generator—they buy reliability during emergencies.
That’s why we focus on system stability, fuel efficiency, and global component sourcing. Our cooperation with Cummins and other international brands ensures that every unit meets real industrial expectations.
We also provide complete solutions including design, installation, testing, and after-sales support, not just equipment delivery.
Q1: How fast does the generator start during power failure?
Usually within 5–10 seconds depending on ATS configuration.
Q2: Can it run continuously for long hours?
Yes, but it is designed mainly for standby use. With proper maintenance, it can support extended operation when needed.
Q3: Is noise level high?
Optional silent canopy can reduce noise significantly, suitable for urban installations.
Q4: What fuel does it use?
Standard diesel fuel with high efficiency engine optimization.
Q5: What is the delivery time?
Typically 15–35 days depending on specifications and order quantity.
A standby generator is not something people think about every day—but when power failure happens, it becomes the most important equipment in the system.
The 45 KVA 35 kW Standby Power Diesel Generator is designed for exactly that moment. It focuses on stability, fast response, and long-term durability. In real industrial applications, these are the factors that matter most.