产品中心
Home > Products > Gas Generator Set > Biogas Generator Set > 50/60 Hz 30 KW Biogas Generator

50/60 Hz 30 KW Biogas Generator

    50/60 Hz 30 KW Biogas Generator

    Ratings *Ratings at 0.8 power factor Performance Data * The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm 3 Dimensions and Weights Engine Brand & Model: HG4B Engine Data How to replace AC alternator belt: ◇Take off fan cover; ◇Take off the 6 pins...
  • Share:
  • Contact us Inquiry
  • E-mail:sf@camda.cc
    WhatsApp:8613712859644

KDGH30-BG    50HZ


Ratings

Rated  PowerkVA37.5
kW30
Voltage type50Hz, 380/220V, 3 phases and 4 wires

*Ratings at 0.8 power factor



Performance Data

Engine Brand & ModelHG4B
Alternator Brand & ModelLSA42.3S5
Control SystemDeepsea DSE6120
Standard Noise Level@7m (Soundproof Sets)75 dBA
Circuit Breaker Type3 Poles MCCB
Frequency & Phase50hz 3Phases + 4Wires
Engine Speed (RPM)1500
Fuel Consumption (Nm3/hr) 100% Load11.09

* The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm3



Dimensions and Weights

ContentOpen typeSoundproof Sets
Dimensions: (mm)L18002370
W7201100
H12801650
Weights (kg)9101437



Engine Brand & Model: HG4B

Engine Data

No. of Cylinders4  in-lineEngine power(KW)33
Cycle4 StrokeCylinder TypeDry
Bore * Stroke (mm)102 * 120Compression Ratio11.5:1
InductionNatural aspiratedDisplacement (L)3.92
Cooling MethodWater cooledGoverning TypeElectronic
Starting method24V DC motorCoolant capacity, including radiator (L)24.79
Lubricant Oil15W40-CF4 or above gradeOil pan capacity (L)11


How to replace AC alternator belt: 

◇Take off fan cover; 

◇Take off the 6 pins which are used to fix the fan on the pulley, then take off the whole discreteness; 

Be careful: Please take care when we take off the fan, and ensure not to mangle the radiator. 

◇Loosen the bracket of alternator and adjusting screw. Take off the used belt, examine there is not any oil stain in the wheel groove, then fit on a new belt;

◇Fit on the fan, fasten the pin and adjust AC alternator belt to be a proper tightness, then fit on the fan. 


How to examine the absorber of crankshaft: 

There is a poise of absorber in a container which is full of liquid. The poise can move in the container to limit the torsion shaking. Checking the absorber whether there is any flute, breach or liquid leaking. If there is any one of them, the absorber must be changed.

The absorber is assembled in the crankshaft, it is in behind of the belt cover which is in front of engine. About how to change absorber, please consult "Operation Manual".


Hot Tags: 50/60 Hz 30 KW Biogas Generator, China, suppliers, manufacturers, factory


50/60 Hz 30 KW Biogas Generator: Complete Technical Guide for Renewable Energy Systems

Introduction to 50/60 Hz 30 KW biogas generator

A 50/60 Hz 30 KW BioGas Generator is a dual-frequency renewable energy power generation system designed to convert biogas into stable electrical energy. It is widely used in farms, wastewater treatment plants, food processing facilities, and small industrial energy systems where organic waste is available as a continuous fuel source.

Unlike conventional fossil fuel generators, this system operates on biogas produced from anaerobic digestion of organic materials such as livestock manure, agricultural residues, food waste, and sewage sludge. The inclusion of 50 Hz / 60 Hz dual-frequency capability makes it suitable for global markets, ensuring compatibility with different regional power standards.

The 30 KW output capacity places this generator in the small-to-medium power range, making it ideal for decentralized energy systems and on-site electricity production.


What Is a 50/60 Hz 30 KW Biogas Generator?

A 50/60 Hz 30 KW biogas generator is an engine-generator set specifically designed to operate using methane-rich biogas fuel while supporting both major global electrical frequencies.

It converts chemical energy into mechanical energy through internal combustion and then into electrical energy through an alternator.

Key Functional Roles:

  • Primary power source for small facilities

  • Off-grid renewable energy system

  • Backup power generator

  • Waste-to-energy conversion system

  • Combined heat and power (CHP) unit

  • Distributed energy solution

This flexibility makes it a highly adaptable solution for global renewable energy applications.


Importance of Dual Frequency (50Hz / 60Hz)

One of the most important features of this generator is its ability to operate under both 50 Hz and 60 Hz electrical standards.

Global Frequency Standards

RegionStandard Frequency
Europe50 Hz
Asia50 Hz
Africa50 Hz
North America60 Hz
South America50/60 Hz mixed
Middle East50 Hz

Benefits of Dual Frequency Systems

  • International deployment flexibility

  • Reduced equipment customization costs

  • Easier export and installation

  • Compatibility with global electrical grids

  • Simplified inventory management


What Is Biogas?

Biogas is a renewable gaseous fuel produced through anaerobic digestion of organic materials.

Composition of Biogas

ComponentPercentage Range
Methane (CH4)50%–75%
Carbon Dioxide (CO2)25%–45%
Hydrogen Sulfide (H2S)0%–3%
Water VaporSaturated
Trace Gases<1%

Methane is the primary energy carrier responsible for combustion.


Working Principle of 50/60 Hz 30 KW Biogas Generator

The generator operates through a multi-stage energy conversion process.

Step 1: Organic Waste Collection

Feedstocks are collected from agricultural or industrial sources.

Feedstock TypeExamples
Livestock WasteCow manure, pig manure
Agricultural WasteStraw, corn stalks
Food WasteRestaurant leftovers
Industrial WasteFood processing residues
Municipal WasteOrganic household waste
Sewage SludgeWastewater treatment solids

Step 2: Anaerobic Digestion

Microorganisms decompose organic matter in oxygen-free environments.

This produces methane-rich biogas over time.


Step 3: Gas Storage

Biogas is stored in gas holders or buffer tanks to ensure stable supply.


Step 4: Gas Purification

Raw biogas is cleaned before use:

  • Hydrogen sulfide removal

  • Moisture separation

  • Particle filtration

  • Pressure stabilization


Step 5: Combustion and Power Generation

The engine burns biogas and converts it into mechanical energy.

The alternator then generates electricity with stable frequency output.


Key Components of 50/60 Hz 30 KW Biogas Generator

biogas engine

Specially designed internal combustion engine optimized for methane fuel.

Features:

  • High combustion efficiency

  • Low emission output

  • Continuous-duty operation

  • Electronic ignition system


Dual Frequency Alternator

Supports both 50 Hz and 60 Hz output standards.

Features:

  • Adjustable speed control

  • Stable voltage regulation

  • High insulation class

  • Industrial durability


Intelligent Control System

Modern control panel ensures automation and safety.

Functions:

  • Automatic start/stop

  • Frequency switching (50/60 Hz)

  • Load monitoring

  • Fault alarms

  • Remote control capability


Cooling System

Maintains safe operating temperature.

Types:

  • Water cooling

  • Radiator cooling

  • Heat exchanger systems


Lubrication System

Ensures engine longevity and reduces friction.


Gas Regulation System

Controls fuel-air mixture for optimal combustion efficiency.


Technical Specifications of 50/60 Hz 30 KW Biogas Generator

ParameterSpecification
Rated Power30 KW
Frequency50 Hz / 60 Hz Dual Mode
Voltage Output400V / 415V / 480V
Power Factor0.8
Fuel TypeBiogas
Methane Requirement≥50%
Engine TypeGas Internal Combustion Engine
Starting SystemElectric Start
Cooling MethodWater Cooled
Operation ModeContinuous Duty
Speed1500 / 1800 RPM
Protection ClassIP23
Control SystemPLC Based Intelligent Controller

Performance Characteristics

Power Stability

The generator maintains stable voltage and frequency even under fluctuating load conditions.


Fuel Efficiency

Efficiency depends on methane concentration and engine tuning.

Methane LevelEfficiency Rating
45%Low
50%Standard
55%Good
60%+High

Load Capacity

Designed for continuous operation between 25%–100% load.


Biogas Consumption Rates

Load LevelConsumption (m³/h)
25% Load12–15 m³/h
50% Load18–22 m³/h
75% Load25–30 m³/h
100% Load32–38 m³/h

Advantages of 50/60 Hz 30 KW Biogas Generator

Dual Frequency Flexibility

Supports global installation requirements.


Renewable Energy Production

Uses organic waste as fuel source.


Low Operating Costs

Reduces electricity and fuel expenses.


Environmental Sustainability

Helps reduce methane emissions and carbon footprint.


Continuous Power Supply

Designed for stable 24/7 operation.


Compact Design

Suitable for small and medium installations.


Applications of 50/60 Hz 30 KW Biogas Generator

Agricultural Farms

Manure-based biogas production for energy generation.


Dairy Facilities

Continuous organic waste supply ensures stable energy production.


Pig and Poultry Farms

High biogas yield from animal waste.


Food Processing Plants

Organic waste streams are ideal for digestion.


Breweries

Wastewater and residues support biogas production.


Wastewater Treatment Plants

Sewage sludge provides continuous biogas fuel.


Rural Energy Systems

Off-grid electricity solutions for remote areas.


Combined Heat and Power (CHP) Applications

Many 30 KW biogas generators are integrated into CHP systems.

Benefits of CHP Systems

  • Higher total energy efficiency

  • Reduced fuel waste

  • Lower operating costs

  • Heat recovery utilization


Heat Recovery Sources

SourceApplication
Engine Cooling WaterHeating systems
Exhaust GasIndustrial heat
Lubrication OilWater heating

Installation Requirements

Site Conditions

  • Proper ventilation

  • Stable foundation

  • Safe gas handling area

  • Easy maintenance access


Electrical Setup

  • Circuit breakers

  • Grounding system

  • Distribution panel

  • Protection relays


Gas Supply System

Stable biogas pressure and flow are required for consistent performance.


Maintenance Guidelines

Daily Maintenance

  • Oil level check

  • Gas pressure monitoring

  • Temperature inspection


Weekly Maintenance

  • Filter cleaning

  • Cooling system check

  • Electrical inspection


Monthly Maintenance

  • Spark plug inspection

  • Sensor calibration

  • Lubrication system check


Annual Maintenance

  • Engine overhaul

  • Alternator testing

  • Full system inspection


Safety Considerations

Gas Safety

Methane detectors and ventilation systems are required.


Fire Protection

Fire extinguishers and emergency shutdown systems must be installed.


Electrical Safety

Proper grounding and overload protection are essential.


Environmental Benefits

Methane Reduction

Captures methane that would otherwise be released into the atmosphere.


Waste Recycling

Transforms organic waste into usable energy.


Carbon Reduction

Supports global decarbonization efforts.


Economic Benefits

Reduced Energy Costs

Onsite power generation reduces electricity bills.


Waste Management Savings

Reduces disposal and treatment costs.


High ROI Potential

Long-term energy savings improve investment returns.


Comparison with Other Renewable Systems

Feature30 KW Biogas GeneratorSolarWind
Continuous OutputYesNoNo
Weather DependencyLowHighHigh
Waste UtilizationYesNoNo
Heat RecoveryYesNoLimited
Off-grid CapabilityHighMediumMedium

Future Development Trends

The 50/60 Hz 30 KW biogas generator market is evolving with new technologies:

  • Smart IoT monitoring systems

  • AI-based performance optimization

  • Higher methane efficiency engines

  • Hybrid renewable systems

  • Advanced emissions control

  • Remote maintenance diagnostics

  • Improved CHP integration


Frequently Asked Questions (FAQ)

What is a 50/60 Hz 30 KW biogas generator?

It is a dual-frequency generator that produces electricity from biogas.

What is its fuel source?

Biogas from anaerobic digestion of organic waste.

Can it operate continuously?

Yes, it is designed for continuous industrial operation.

What is the biogas consumption?

Approximately 32–38 m³/h at full load.

Why dual frequency is important?

It allows global compatibility with both 50 Hz and 60 Hz power systems.




The 50/60 Hz 30 KW Biogas Generator is a highly versatile renewable energy system designed for global applications. With dual-frequency capability, efficient biogas utilization, and stable power output, it provides an effective solution for waste-to-energy conversion across agriculture, industry, and municipal sectors.

Its ability to operate continuously, reduce emissions, and support decentralized energy systems makes it a key technology in the transition toward sustainable energy infrastructure worldwide.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!

This website uses cookies to ensure you get the best experience on our website.

Accept Reject