KDGC50S 50HZ

Our product lines are designed with state-of-the-art technologies to provide standby power, distributed power generation, and auxiliary power for a wide range of needs. Anytime, anywhere, Cummins generators are ready to keep you up and running, no matter what.
We insist on taking the tenet “Service one, satisfy one” to improve technology innovation, continue developing cost-effective products, and will continue obtaining customers’ trust by quality, having a foothold in the market by reputation, bringing benefit to society by values, galloping in the future by strength, cooperating with societies and creating a prosperous tomorrow.
Ratings
Standby Power KVA 63 KW 50 Prime Power KVA 56 KW 45 Voltage type 50Hz, 380/220V, 3 phases and 4 wires
Performance Data
Engine Brand & Model Cummins 4BTA3.9-G2 Alternator Brand & Model Leroy Somer LSA42.3L9 Control System Deepsea DSE6120 Standard Noise Level@7m (Soundproof Sets) 75 dBA Circuit Breaker Type 3 Poles MCCB Frequency & Phase 50hz 3Phases + 4Wires Engine Speed (RPM) 1500 Fuel Consumption (L/hr) (100% Load) 11.25
Dimensions and Weights
Content Open type Soundproof Sets Dimensions: (mm) L 1800 2370 W 760 1100 H 1400 1650 Weights (kg) 900 1506

Hot Tags: 60 KVA Standby Diesel Generator, China, suppliers, manufacturers, factory
60 KVA Standby Diesel Generator – Reliable Backup Power You Can Count On
I’ve worked with industrial power systems for many years, and if there is one thing I’ve learned, it is this: power failure never comes at a convenient time. That is exactly why I focus on dependable backup systems like the 60 KVA Standby Diesel Generator. In this article, I will walk you through how I understand this generator, how it works in real life, and why many industries choose it as their emergency power backbone.
A 60 KVA Standby Diesel Generator is a backup power system designed to automatically supply electricity when the main grid fails. In simple words, it “kicks in” when your normal power goes down. I usually explain it like this to customers: it is like a spare engine for your whole building.
At Camda New Energy Equipment Co. Ltd., we design this generator for stable performance, low fuel consumption, and long running hours. It is powered by a diesel engine, often paired with well-known brands such as Cummins-based systems, ensuring durability and strong output under load.
| Specification | Value | Industry Standard Reference |
|---|---|---|
| Power Rating | 60 KVA / 48 kW | ISO 8528 Generator Standard |
| Frequency | 50 / 60 Hz | IEC Electrical Standards |
| Phase | 3 Phase | Industrial Power Distribution Norm |
Many customers ask me how a standby generator works. I keep it simple. Inside the system, there are three key parts: the engine, the alternator, and the control system.
Engine: Burns diesel fuel to create mechanical energy.
Alternator: Converts mechanical energy into electricity.
Control Panel: Detects power loss and starts the generator automatically.
When grid power fails, the automatic transfer switch (ATS) sends a signal. Within seconds, the generator starts and takes over the load. This is why we call it a standby system—it waits quietly until it is needed.

From my experience in factory testing and customer feedback, these are the most important features that matter in real operation:
Automatic start and stop system
Stable voltage output under heavy load
Fuel-efficient diesel engine design
Low maintenance structure
Strong overload handling capacity
Noise reduction enclosure optional
Compared to smaller units, a 60 KVA standby generator is more stable when powering mixed loads like motors, HVAC systems, and IT equipment.
| Feature | 60 KVA Generator | Smaller 30 KVA Unit |
|---|---|---|
| Load Stability | High | Medium |
| Fuel Efficiency | Optimized for medium load | Good but limited capacity |
| Application Range | Industrial + Commercial | Residential + Light use |
At Camda, we don’t just assemble generator sets—we engineer them for long-term use. Our factory follows ISO9001 and ISO14001 systems, which means every step is controlled, from welding the base frame to final load testing.
One thing I always emphasize is engine matching. A generator is only as strong as its engine. That is why we cooperate with global brands like Cummins, Perkins, and other leading suppliers. This ensures stable combustion, lower vibration, and longer service life.
We also perform 100% load testing before shipment. Every unit must pass full capacity testing for at least 1–2 hours to simulate real working conditions.
| Test Item | Requirement | Camda Standard |
|---|---|---|
| Load Test | ≥ 100% rated load | Passed 110% overload test |
| Voltage Stability | ±1% to ±2% | Within ±1.5% |
| Noise Level | Industry dependent | 70–75 dB(A) optional silent canopy |
I have seen the 60 KVA Standby Diesel Generator installed in many different environments. It is not limited to one industry. Its flexibility is what makes it valuable.
Construction sites – for tools, lighting, and machinery
Manufacturing plants – stable production power supply
Hospitals – emergency backup for life-support systems
Telecommunication stations – uninterrupted signal power
Data centers – IT system protection
Farms – irrigation and equipment operation
For industries where downtime equals financial loss, this generator acts as a safety shield.

From raw steel cutting to final packaging, I can say every step matters. At Camda, we use CNC cutting, precision welding, and corrosion-resistant coating to build the base frame.
After assembly, each generator goes through:
Engine inspection
Electrical wiring verification
Full load testing
Safety shutdown simulation
We also follow CE certification requirements and export packaging standards, using wooden crates or steel frames depending on shipping method.
| Process Stage | Quality Check | Standard Reference |
|---|---|---|
| Assembly | Torque & alignment check | ISO 8528 |
| Electrical System | Insulation & safety test | IEC 60034 |
| Final Testing | Load & runtime test | Factory internal protocol |
I often tell customers that choosing a generator is not just about price—it’s about long-term reliability. Camda has been in this industry since 1998, and over the years, we moved from simple diesel systems to advanced gas and hybrid energy solutions.
Here is what makes us different:
Over 25 years manufacturing experience
3000 units annual production capacity
Global engine partnerships (Cummins, Perkins, GE Jenbacher)
Strict ISO and CE compliance
Full engineering and after-sales support
We don’t just sell equipment—we provide a complete power solution from design to maintenance.
Q1: How long can a 60 KVA standby generator run continuously?
A: It can typically run 8–24 hours depending on fuel tank capacity and load conditions.
Q2: Is installation complicated?
A: No. We provide full technical support, wiring diagrams, and optional on-site guidance.
Q3: What fuel efficiency can I expect?
A: On average, it consumes around 12–15 liters per hour at 75% load.
Q4: Can it be customized?
A: Yes. We offer customization for voltage, frequency, enclosure type, and control systems.
Q5: What is the delivery time?
A: Usually 15–35 days depending on specifications and order size.

From my perspective, a 60 KVA Standby Diesel Generator is not just a machine—it is a guarantee that your business keeps running when everything else stops. With strong engineering, strict manufacturing control, and proven engine partnerships, Camda focuses on delivering reliable backup power that people can trust in real situations.