camda KDGC series Diesel Generator Sets are powered by world-famous Cummins engines, coupled with durable Leroy Somer or Stamford alternators, controlled by advanced controllers like UK Deepsea or Czech ComAp.
Our soundproof canopy type diesel gensets features:
1.All canopy parts are designed with modular assembly.
2.Doors on canopy each side
3.All metal canopy parts are painted by electrostatic polyester powder paint, painted against corrosion and weatherproof.
4.Emergency stop push button is installed on the outside of sound-proof canopy.
5.Especially chosen soundproof materials to decrease noise level.
6.Exhaust silencer is protected against various environment conditions.
7.Exhaust system is insulated thermally from other parts.
8.Easy lifting and moving, convenient operation and maintenance.
Application scope:
Cummins Powered Silent Diesel Generator is suitable for environment with high requirement for noise reduction, such as residential area, high-end office buildings, hotels, scientific research institutes, hospitals, universities and colleges, etc.

Camda diesel generator sets powered by Cummins, silent type.
50Hz 3 phases+4 wires, 400/230V, pf 0.8.Genset Model Standby power Prime Power Engine Model Alternator Model Dimension
L×W×H(mm)Silent Canopy kVA kW kVA kW KDGC22S 27 22 25 20 4B3.9-G2 PI144E 2350×1133×1516 KDGC32S 40 32 35 28 4BT3.9-G2 PI144H 2350×1133×1516 KDGC44S 55 44 50 40 4BTA3.9-G2 UCI224D 2350×1133×1516 KDGC53S 66 53 60 48 4BTA3.9-G2 UCI224E 2350×1133×1516 KDGC69S 86 69 76 6 4BTA3.9-G11 UCI224G 2350×1133×1516 KDGC77S 96 77 87 70 6BT5.9-G2 UCI224G 3200×1133×1766 KDGC88S 110 88 100 80 6BT5.9-G2 UCI274C 3200×1133×1766 KDGC100S 125 100 114 91 6BTA5.9-G2 UCI274D 3200×1133×1766 KDGC118S 148 118 135 108 6BTAA5.9-G2 UCI274E 3200×1133×1766 KDGC140S 175 140 160 128 6CTA8.3-G2 UCI274F 3600×1333×1940 KDGC160S 200 160 182 145 6CTA8.3-G2 UCI274G 3600×1333×1940 KDGC176S 220 176 200 160 6CTAA8.3-G2 UCI274H 3600×1333×1940 KDGC200SL 250 200 225 180 6LTAA8.9-G2 UCDI274J 3600×1333×1940 KDGC220SL 275 220 250 200 6LTAA8.9-G2 UCDI274K 3600×1333×1940 KDGC200S 250 200 225 180 NT855-GA UCDI274J 4300×1483×2145 KDGC220S 275 220 250 200 NT855-GA UCDI274K 4300×1483×2145 KDGC220SM 275 220 250 200 MTA11-G2A UCDI274K 4300×1483×2145 KDGC260S 325 260 300 240 NTA855-G1A HCI444D 4300×1483×2145 KDGC280S 350 280 320 256 NTA855-G1B HCI444ES 4300×1483×2145 KDGC280SM 350 280 320 256 MTAA11-G3 HCI444ES 4500×1583×2100 KDGC310S 385 310 350 280 NTA855-G2A HCI444E 4300×1483×2145 KDGC315S 394 315 350 280 NTA855-G4 HCI444E 4300×1483×2145 KDGC330S 413 330 375 300 NTAA855-G7 HCI444F 4500×1583×2100 KDGC360S 450 360 400 320 NTAA855-G7A HCI444F 4500×1583×2100 KDGC400SQ 500 400 450 360 QSZ13-G2 HCI544C 5000×1983×2371 KDGC400S 500 400 450 360 KTA19-G3 HCI544C 4800×1683×2200 KDGC440SQ 550 440 500 400 QSZ13-G3 HCI544D 5000×1983×2371 KDGC440S 550 440 500 400 KTA19-G3A HCI544D 4800×1683×2200 KDGC440S 550 440 500 400 KTA19-G4 HCI544D 4800×1683×2200 KDGC480S 600 480 550 440 KTAA19-G5 HCI544E 5000×1983×2371 KDGC528S 660 528 600 480 KTA19-G8 HCI544E 4800×1683×2200 KDGC550S 688 550 625 500 KTAA19-G6A HCI544FS 5000×1983×2371 KDGC640S 800 640 728 582 KT38-GA LVI634B 6058×2438×2896 KDGC660S 825 660 750 600 KTA38-G2 LVI634B 6058×2438×2896 KDGC704S 880 704 800 640 KTA38-G2B HCI634H 6058×2438×2896 KDGC800S 1000 800 910 728 KTA38-G2A HCI634H 6058×2438×2896 KDGC880S 1100 880 1000 800 KTA38-G5 HCI634J 6058×2438×2896 KDGC1000S 1250 1000 1138 910 KTA38-G9 LVI634G 6058×2438×2896 KDGC1100SQ 1375 1100 1250 1000 QSK38-G5 HCI634K 12192×2438×2896 KDGC1100S 1375 1100 1250 1000 KTA50-G3 LVI 634G 12192×2438×2896 KDGC1232S 1540 1232 1400 1120 KTA50-G8 PI734B 12192×2438×2896 KDGC1320S 1650 1320 1500 1200 KTA50-GS8 PI734C 12192×2438×2896 KDGC1500S 1875 1500 -- -- KTA50-G15 PI734E 12192×2438×2896
Camda diesel generator sets powered by Cummins, silent type.
60Hz 3 phases+4 wires, 220/127V, pf 0.8.Genset Model Standby power Prime power Engine Model Alternator Model Dimension
L×W×H(mm)Weight (kg) Silent Canopy kVA kW kVA kW KDGC27S1 33 27 30 24 4B3.9-G2 PI144E 2350×1133×1516 1390 KDGC33S1 41 33 37.5 30 4BT3.9-G2 PI144G 2350×1133×1516 1420 KDGC56S1 70 56 62 50 4BTA3.9-G2 UCI224D 2350×1133×1516 1540 KDGC83S1 103 83 94 75 6BT5.9-G2 UCI224F 3200×1133×1766 2001 KDGC100S1 125 100 114 91 6BT5.9-G2 UCI274C 3200×1133×1766 2059 KDGC116S1 145 116 131 105 6BTA5.9-G2 UCI274D 3200×1133×1766 2090 KDGC132S1 165 132 150 120 6BTAA5.9-G2 UCI274E 3200×1133×1766 2178 KDGC167S1 210 167 190 152 6CTA8.3-G2 UCI274F 3600×1333×1940 3050 KDGC192S1 240 192 220 175 6CTAA8.3-G2 UCI274G 3600×1333×1940 3204 KDGC240SL1 300 240 273 218 6LTAA8.9-G2 UCDI274J 3600×1333×1940 3390 KDGC220S1 275 220 250 200 NT855-GA UCI274H 4300×1483×2145 4120 KDGC280S1 350 280 320 256 NTA855-G1 HCI444D 4300×1483×2145 4470 KDGC280S1 350 280 320 256 NTA855-G1B HCI444D 4300×1483×2145 4470 KDGC352S1 440 352 400 320 NTA855-G3 HCI444E 4300×1483×2145 4515 KDGC400S1 500 400 438 350 KTA19-G2 HCI444FS 4800×1683×2200 6440 KDGC440S1 550 440 500 400 KTA19-G3 HCI544C 4800×1683×2200 6520 KDGC496S1 620 496 565 450 KTA19-G4 HCI544C 4800×1683×2200 6600 KDGC550S1 688 550 588 470 KTAA19-G5 HCI544D 5000×1983×2371 6720 KDGC600S1 750 600 682 546 KTAA19-G6A HCI544E 5000×1983×2371 6800 KDGC680S1 850 680 775 620 KT38-G HCI544F 6058×2438×2896 11667 KDGC800S1 1000 800 906 725 KTA38-G2 HCI634G 6058×2438×2896 11947 KDGC880S1 1100 880 1000 800 KTA38-G2A LVI634C 6058×2438×2896 12834 KDGC1000S1 1250 1000 1125 900 KTA38-G4 HCI634H 6058×2438×2896 13170 KDGC 1232S1 1540 1232 1400 1120 KTA50-G3 HCI634K 12192×2438×2896 17020 KDGC1386S1 1732 1386 1575 1260 KTA50-G9 PI734B 12192×2438×2896 18200
Hot Tags: cummins powered silent diesel Generator, China, suppliers, manufacturers, factory
Cummins Powered Silent Diesel Generator
When I talk to customers about backup power systems, I usually start from a very simple point: electricity is something you only notice when it disappears. Once the grid goes down, everything changes immediately—production stops, communication breaks, and operations slow down. That is exactly why the Cummins Powered Silent Diesel Generator is widely used across industries that cannot afford downtime.
At Camda New Energy Equipment Co. Ltd., I have worked with many different power projects, and one thing is always clear: people don’t just want electricity, they want stable, quiet, and reliable electricity that they don’t have to worry about.
This generator is designed for standby and emergency power supply. It uses a Cummins engine as the core power source and a soundproof enclosure to reduce noise levels significantly.
I usually explain it in a simple way: it is a strong engine inside a quiet box. It works hard, but you barely hear it.
| Specification | Value | Source |
|---|---|---|
| Power Range | 20 kVA – 2000 kVA | Camda Engineering Data |
| Engine Brand | Cummins Diesel Engine | Cummins Technical Manual |
| Noise Level | 65–75 dB @ 7m | ISO 3744 Acoustic Standard |
Inside the system, there are four main parts: engine, alternator, control system, and soundproof structure.
I like to break it down in a simple way: the engine creates power, the alternator converts it into electricity, and the control system manages everything automatically.
When power fails, the ATS system detects it instantly and starts the generator within seconds. The transition is smooth and automatic.

| Component | Function | Reference |
|---|---|---|
| Cummins Engine | Mechanical energy generation | Cummins Global Datasheet |
| Brushless Alternator | Electricity conversion | IEC 60034 Standard |
| Smart Controller | Monitoring and protection | Deep Sea Electronics Guide |
| Silent Canopy | Noise reduction system | ISO 3744 Acoustic Standard |
From real installation experience, I notice customers focus on five key things: noise control, fuel efficiency, stability, durability, and ease of maintenance.
Advanced soundproof enclosure for low noise operation
Stable voltage output under load changes
High fuel efficiency Cummins engine system
Automatic start via ATS system
Compact design for easy installation
| Feature | Benefit | Industry Standard |
|---|---|---|
| Silent Design | Noise reduction for urban use | ISO 3744 |
| Fuel Efficiency | Lower running cost | Cummins Performance Report |
| Automatic Start | Fast power recovery | IEC 60947 ATS Standard |
At Camda, we don’t just assemble generators. We design full power systems that must work in real-world conditions, not just in theory.
We use global brands like Cummins, Perkins, Yuchai, Stamford, Leroy Somer, ABB, and Schneider to ensure long-term stability and consistent performance.
Each generator is tested under different load conditions before shipment to make sure it performs well under real operating environments.
| Technical Element | Advantage | Source |
|---|---|---|
| Cummins Engine Technology | Long lifespan and stable output | Cummins Engineering Manual |
| Brushless Alternator | Low maintenance operation | IEC 60034 Standard |
| Full Load Testing | Verified real performance | ISO 8528 Testing Protocol |
The Cummins powered silent diesel generator is widely used in environments where both power stability and low noise are important.
Hospitals and healthcare facilities
Residential and commercial buildings
Telecommunication stations
Data centers
Construction sites in urban areas
In these environments, noise control is not optional—it is a requirement.
From steel frame production to final testing, every step is controlled carefully. I always believe that quality is built during manufacturing, not checked at the end.
| Stage | Process | Standard |
|---|---|---|
| Frame Fabrication | Steel cutting and welding | ISO 9001 System |
| Assembly | Engine and alternator integration | Factory Inspection Process |
| Final Testing | 0%–100% load test | ISO 8528 Standard |
We also follow ISO14001 environmental management and OHSAS safety systems to ensure responsible production and safe working conditions.
From my experience, customers don’t buy just a generator—they buy stability during unexpected power failure.
Camda has been manufacturing generator sets since 1998 and works closely with global brands like Cummins, Perkins, Yuchai, Stamford, Leroy Somer, ABB, and Schneider. This allows us to deliver stable, tested, and reliable power systems worldwide.
We also provide full support including design, production, testing, packaging, shipping, and after-sales service.

Q1: How quiet is the silent generator?
Typically 65–75 dB depending on load and installation conditions.
Q2: Can it run continuously?
Yes, it is designed for standby and long-hour operation with proper maintenance.
Q3: Does it support automatic start?
Yes, it works with ATS for automatic start and stop.
Q4: What fuel does it use?
Standard diesel fuel optimized for Cummins engines.
Q5: What is the delivery time?
Usually 15–35 days depending on configuration.
A silent generator is not just about reducing noise—it is about making power invisible in daily life. When everything is running normally, you don’t hear it, you don’t notice it. But when power fails, it becomes the most important system in the building.
The Cummins Powered Silent Diesel Generator is designed for exactly that role: quiet, stable, and reliable power when it matters most.
This website uses cookies to ensure you get the best experience on our website.